Click or drag to resize

CCHIMERAClipToDetectLimit Method

Apply detection limit clipping of data.

Namespace:  Geosoft.Desktop.GXNetX
Assembly:  geosoft.desktop.gxnetx (in geosoft.desktop.gxnetx.dll) Version: 2025.1.0.25
Syntax
public static void ClipToDetectLimit(
	CGXNETCore gxNetShared,
	CVV vv,
	double det_limit,
	int conv
)

public static void ClipToDetectLimit(
	CGXNETCore gxNetShared,
	CVV vv,
	double det_limit,
	int conv
)

Parameters

gxNetShared
Type: GeoEngine.Core.GXNetXCGXNETCore
A shared CGXNETCore
vv
Type: GeoEngine.Core.GXNetXCVV
Input data vv (altered).
det_limit
Type: SystemDouble
Detection limit
conv
Type: SystemInt32
Auto-convert negatives?
Remarks
Flow: 1. If auto-converting negatives, then all negative values are replaced by -0.5*value, and detection limit is ignored. 2. If not auto-converting negatives, and the detection limit is not <define>rDUMMY</define>, then values less than the detection limit are converted to one-half the detection limit.